How to Drain AC Compressor Oil
Open the tank drain valve after every use and let the oil and water flow out, or fit a timer-operated drain valve that opens the drain on its own at set intervals.

On this page
Top picks at a glance
As an Amazon Associate I earn from qualifying purchases.
- 1
Automatic Electronic Tank Drain Kit9.6/10View on Amazon - 2
Extended Tank Drain Valve Assembly Kit Flexible9.6/10View on Amazon - 3
Hromee Extended Tank Drain Assembly Kit with 109.5/10View on Amazon
How to drain AC compressor oil? Open the drain valve at the bottom of the tank and let the water and oil that collect there flow out, then close the valve. The drain sits at the lowest point of the tank, where moisture that condenses while the compressor runs collects with oil and sediment, so opening the valve lets the mix out before water, oil and sediment combine into sludge. That valve drains the tank, not the compressor pump, so an oil change follows the compressor manual. A braided steel hose brings the drain point out where you can reach it, and a timer-operated valve can open the drain on its own at set intervals.
GarageToolHQ earns a commission when you buy through links on our product pages, at no extra cost to you. Read our affiliate disclosure.
Below: the steps for draining the tank, manual valves versus a timer-operated drain, and the gear that makes the job easier.
| # | Product | Shop Score | Buy |
|---|---|---|---|
| 1 | Automatic Electronic Tank Drain Kit | 9.6/10 | Buy on Amazon |
| 2 | Extended Tank Drain Valve Assembly Kit Flexible | 9.6/10 | Buy on Amazon |
| 3 | Hromee Extended Tank Drain Assembly Kit with 10 | 9.5/10 | Buy on Amazon |

Automatic Electronic Tank Drain Kit
A timer-operated automatic tank drain kit with a 1/4 inch NPT valve, a flexible braided steel tube and a strainer and ball valve, rated IP65 for a 32 to 140 degree F ambient range.
Pros
- Timer opens the valve automatically at the set interval
- Off interval adjusts from 0.5 to 50 minutes; discharge from 0.5 to 10 seconds
- Strainer and ball valve resist clogging from oil and sludge
- Rated IP65 with a 32 to 140 degree F ambient range
Cons
- Needs a mains outlet: the timer runs on AC 110V-120V/60Hz power
- Interval and discharge time must be set by hand
- More parts than a manual valve: timer, strainer and ball valve to look after
- No warranty term is stated

Extended Tank Drain Valve Assembly Kit Flexible
An extended tank drain valve kit with a 15 inch braided steel tube, a 1/4 inch quarter-turn drain valve and a brass adapter, rated to a maximum pressure of 300 PSI.
Pros
- 15 inch braided steel tube flexes without breaking or kinking
- Rated to a maximum pressure of 300 PSI
- Pre-applied thread sealant on the male threads, plus seal tape in the box
- 3/8 inch Male by 1/4 inch Female brass adapter joins different pipe ends
Cons
- Manual valve: open and close it by hand each time
- No timer, so draining depends on remembering the job
- About 17 inches overall, a short run from the drain port
- No warranty term is stated

Hromee Extended Tank Drain Assembly Kit with 10
An extended tank drain kit with a 10 inch braided steel hose, a chrome-plated brass ball valve and an elbow fitting, rated to 175 PSI maximum working pressure.
Pros
- 10 inch braided steel hose prevents breaking and kinks
- Chrome-plated brass ball valve with a rubber-wrapped lever handle
- Ball valve rated to 300 PSI at up to 212 degrees F
- Elbow with pre-applied thread sealant and seal tape included
Cons
- 10 inch hose gives the least reach here
- Maximum working pressure of 175 PSI, below the 300 PSI rating of its own ball valve
- Manual valve with no timer or automatic draining
- No strainer is included to guard the valve against sludge
How to drain AC compressor oil from the tank
Check the compressor manual for the drain routine before you start, then work through the steps below.
- Find the drain valve. It sits at the bottom of the tank. If the valve is tucked under the tank, fit an extended drain kit so the valve sits where you can reach it.
- Open the valve. A quarter-turn valve or a ball valve with a lever handle opens the drain, and the braided steel hose carries the flow out from under the tank.
- Let the oil and water flow out. Water, oil and sediment drain together, so let the flow run until it stops.
- Close the valve. Shut the valve once the flow stops.
- Drain the tank after every use. Moisture condenses in the tank each time the compressor runs, so draining after use keeps water from building up.
- Set a timer if the valve is automatic. Set the off interval between 0.5 and 50 minutes and the discharge time between 0.5 and 10 seconds.
Your compressor manual states the drain routine for that tank. Follow it before fitting any drain kit, and check that the fittings match the drain port.
Drain the tank after use so water does not rust it from the inside, never exceed the tool's rated pressure, wear eye protection, and run 240V units on the circuit the manual calls for. Do not run a gas engine compressor in a closed garage. Read our Safety Disclaimer.
Manual drain valves vs an automatic timer drain
A manual valve needs no power and nothing but a hand to open it, but draining depends on remembering the job after every use. The two manual kits here bring the valve out on a braided steel hose, one 15 inches long and one 10 inches long.
An automatic timer drain opens the valve on its own at the interval you set, which suits a compressor that runs often. The timer kit here runs on AC 110V-120V/60Hz through a three-prong plug, and a strainer and ball valve guard it against clogging when water, oil and sediment combine into sludge.
Match the kit to the compressor. The manual kits state their pressure ratings: the Kbrotech kit (on Amazon) is rated to a maximum pressure of 300 PSI, and the Hromee ball valve is rated to 300 PSI at up to 212 degrees F, with a maximum working pressure of 175 PSI. The timer kit states no pressure rating, so check the compressor manual before fitting it.
The gear for draining AC compressor oil
The drain step needs a valve and a hose that reach out from under the tank, and the timer kit adds the schedule, so the three kits below cover the job from manual draining to automatic draining.
FAQ: garage tools
How often should I drain my air compressor tank?
After every use. The moisture in the air condenses in the tank each time the compressor runs, so draining the tank after use keeps water from building up. A timer-operated drain valve can open the drain on its own at the interval you set.
What comes out when I drain an air compressor tank?
Water, oil and sediment. The moisture that condenses while the compressor runs collects in the tank with oil and sediment, and the three combine to form sludge that can clog a plain valve. A strainer and ball valve guard the valve against that clogging.
Can I fit an automatic drain valve to my compressor?
Yes, if the drain port matches. The timer kit here fits a 1/4 inch NPT drain port, and its timer runs on AC 110V-120V/60Hz through a three-prong plug. Set the off interval and the discharge time, and the valve opens on its own.
What size fitting does a compressor drain valve use?
Check the drain port on your compressor first. The three kits here use 1/4 inch NPT threads. The manual kits include a 3/8 inch Male by 1/4 inch Female hex bushing brass adapter for joining pipes with different end sizes, and the timer kit includes a 1/2 by 1/4 inch MNPT strainer and ball valve with a 3/8 Male by 1/4 Female bushing adapter.
Why does water come out with the oil?
Because the moisture in the air condenses in the tank each time the compressor runs. That water collects in the tank with oil and sediment, so the drain releases water and oil together. Draining the tank after every use keeps the water from building up.
Related: the best 1/4-inch auto drain valve for an air compressor, air compressor maintenance, air compressor oil types and the engine and shop equipment hub.