How to Set Up Air Pump With Check Valve: Threads, Direction and Steps
Set up an air pump with a check valve by matching thread sizes, fitting the valve with its outlet to the tank, and connecting the unloader port where fitted.

On this page
Top picks at a glance
As an Amazon Associate I earn from qualifying purchases.
- 1
New In tank Check valve for air compressor 1/2"9.6/10View on Amazon - 2
New In tank Check valve for air compressor 3/4"9.5/10View on Amazon - 3
Joywayus 3-Way Brass Male Threaded Air Compressor9.4/10View on Amazon - 4
New In tank Check valve for air compressor 1/2"9.4/10View on Amazon
The compressor fills the tank, shuts off, and then air hisses back toward the pump while the tank pressure falls away. How to set up air pump with check valve work starts with that backflow: fit the valve between the pump and the tank with its outlet to the tank, on a shut-down and depressurized machine, with the thread sizes matched to the ports in hand. The valve then lets air pass toward the tank and blocks the return path when the pump stops.
GarageToolHQ earns a commission when you buy through links on our product pages, at no extra cost to you. Read our affiliate disclosure.
Below: what the valve does, thread sizes to match, fitting steps, and the valves for the job.

New In tank Check valve for air compressor 1/2"
A brass in-tank check valve with a 1/2-inch compression top inlet and a 1/2-inch male NPT outlet, rated at 450 PSI and 20 SCFM, with a 1/8-inch unloader port, holding tank air from flowing back to the pump.
Pros
- 450 PSI max pressure, 20 SCFM flow rate
- 1/2-inch compression inlet, 1/2-inch male NPT outlet
- 1/8-inch unloader port included
- Brass body, made in the USA
Cons
- No warranty term stated
- No seal material stated
- No compression nut or ferrule mentioned
- Single valve in the pack, no spare included

New In tank Check valve for air compressor 3/4"
An in-tank check valve with 3/4 inch FPT by 3/4 inch MPT connections and a 1/8 inch unloader port, for the pump-to-tank path.
Pros
- Stated figures: 450 PSI max, 400 deg F max, 30 SCFM flow
- 1/8 inch unloader port included
- 3/4 inch FPT by MPT in-tank format
- Maker states it is made in USA
Cons
- Fits 3/4 inch port setups only
- Unloader port is 1/8 inch only
- No warranty term is stated
- In-tank format, not a 3-way tube format

Joywayus 3-Way Brass Male Threaded Air Compressor
A 3-way brass check valve with G1/2 by G3/8 by G1/8 male threads for tube, tank and compressor piston pump connections.
Pros
- Three male connectors for tube, tank and pump
- High strength brass with corrosion resistance stated
- Made as a replacement for an old or broken valve
- G-thread sizes stated for all three ends
Cons
- All three ends are male thread
- G-thread sizes must match G ports
- No warranty term is stated
- 3-way format, not an in-tank format

New In tank Check valve for air compressor 1/2"
A brass in-tank check valve with a 1/2-inch female NPT inlet and a 1/2-inch male NPT outlet, with a 1/8-inch female NPT side unloader port, for pump lines that end in a female thread.
Pros
- 1/2-inch female NPT inlet, 1/2-inch male NPT outlet
- 1/8-inch female NPT side unloader port
- Thread diameters stated for each port
- Brass construction
Cons
- No max pressure stated
- No flow rate stated
- No warranty term stated
- No seal material stated
How to set up air pump with check valve: what the valve does
A check valve passes air in a single direction. It sits on the path from the pump to the tank: air moves into the tank while the pump runs, and the valve closes the return path when the pump stops, so tank air does not push back through the pump.
Two formats appear below. An in-tank valve threads into the tank port, with its male outlet to the tank. The 3-way valve below carries three male connectors for tube connecting, the air pressure tank and the compressor piston pump. The ports on your machine decide which format fits.
Thread sizes and stated limits to match first
Match the valve to the ports first. The table uses the same figures as the cards below.
| Valve | Connections | Stated figures |
|---|---|---|
| CHECK VALVE 43219 | 3/4 inch FPT by 3/4 inch MPT, with 1/8 inch unloader port | 450 PSI max pressure, 400 deg F max temperature, 30 SCFM flow rate |
| Joywayus 3-Way Brass | G1/2 by G3/8 by G1/8 male threads | Not stated |
| Conrader 1/2 Comp | 1/2 inch comp by 1/2 inch mpt | Not stated |
| Conrader 1/2 FPT | 1/2 inch FPT by 1/2 inch MPT | Not stated |
Thread names matter as much as size: FPT and MPT ends, a comp end and G-thread ends are different connections. For the 3/4 inch NPT valve, the maker notes that 3/4 inch NPT measures 1.050 on a tape measure. Where a limit is Not stated, confirm it with the maker before fitting.
How to set up air pump with check valve: the fitting steps
- Shut the compressor down and relieve the pressure completely. The Joywayus maker states this step before replacing a valve. No fitting work starts on a pressurized tank.
- Match every thread. Compare the tank port, pump outlet and tube connection against the valve ends in the table above, thread type as well as size. For a 3/4 inch NPT male thread, use the maker’s tape note of 1.050.
- Fit the valve with its outlet to the tank. On the 3-way valve, connect the three male connectors to the tube, the air pressure tank and the compressor piston pump as its maker describes.
- Connect the unloader port where fitted. The 3/4 inch valve includes a 1/8 inch unloader port. Route that connection as the compressor manual directs for your machine.
- Check the stated limits against your machine. The 3/4 inch valve states 450 PSI max pressure, 400 deg F max temperature and a 30 SCFM flow rate. For valves with limits Not stated, confirm the figures with the maker before use.
- Start the compressor as its manual directs and check the joints. Watch the new connections while the tank fills, and confirm the tank holds pressure after shutoff, with no steady hiss from the valve.
Shut the compressor down and relieve the tank pressure completely before a valve comes off or goes on. The tank side of the fitting stays pressurized until you relieve it.
Drain the tank after use so water does not rust it from the inside, never exceed the tool's rated pressure, wear eye protection, and run 240V units on the circuit the manual calls for. Do not run a gas engine compressor in a closed garage. Read our Safety Disclaimer.
The Gear: Four Check Valves for the Thread-Matching Step
The thread-matching step above is where these four valves earn their place, each covering a different port format on the pump-to-tank path.
FAQ: garage tools
Which way round does an air compressor check valve go?
With its outlet to the tank, as the maker of the 3/4 inch in-tank valve describes its male end. Air passes toward the tank, and the return path closes when the pump stops.
What is the small port on an in-tank check valve for?
The 3/4 inch valve below includes a 1/8 inch unloader port. Connect that port as the compressor manual directs for your machine.
How do I confirm a 3/4 inch NPT port size?
Use the maker’s tape note: 3/4 inch NPT measures 1.050 on a tape measure. Measure the male thread against that figure, then match the FPT and MPT ends of the valve to the ports in hand.
Can I replace a check valve with the tank still pressurized?
No. The Joywayus maker states the step plainly: before replacing the valve, make sure the compressor is totally shut down and pressure is relieved completely.
What pressure rating does a check valve need?
Compare the maker’s stated limit with your machine. The 3/4 inch valve states 450 PSI max pressure, 400 deg F max temperature and a 30 SCFM flow rate; the others state no such figures, so confirm them with the maker.
Related: air compressor check valve repair steps, the air compressor valve types guide, our picks for the best one way check valve for air compressor and the air compressors hub. Also see air compressor pump parts.